Most peptide orders in South Africa start with a lyophilised vial. The trouble is what comes next. The vial arrives as a small cake of freeze-dried powder, and turning that into a filled pen cartridge needs a handful of extra pieces: a pen body, a cartridge, tips, a syringe, swabs and a diluent. Forget one of them and the work stalls until the next courier run.
That's the gap the Biolabs Vial-to-Pen Starter Kit and Vial-to-Pen Refill Kit were put together to close. This guide walks through what's in each kit, how the two fit together, and how a typical lab moves from a sealed vial to a loaded cartridge.
What is a vial-to-pen kit?
A vial-to-pen kit is a bundle of the hardware and consumables you need to transfer a reconstituted research peptide from its vial into a 3 ml pen cartridge. It isn't a peptide product. There's no compound inside the box, and the vial itself is always bought separately.
On the store you'll see both kits offered as an add-on on vial product pages. Add one there and it drops into the cart alongside the vial, so the peptide and its hardware ship together.
The Vial-to-Pen Starter Kit
The Starter Kit is for a lab setting up pen hardware for the first time. According to the product page, it contains:
- 1 × Biolabs 80IU Re-usable Pen (black)
- 1 × 3 ml cartridge
- 20 × 31G 5 mm pen tips
- 1 × Reconstitution Kit (4 × alcohol swabs, 1 × 21G needle, 1 × 3 ml syringe)
The pen is the reusable metal-body model with an 80-unit dial, built around standard 3 ml cartridges. Because the body is reusable, it's a one-off purchase. Everything else in the box is a consumable.
The Vial-to-Pen Refill Kit
Once a lab has a pen, there's no reason to buy another one with every vial. The Refill Kit drops the pen body and keeps the consumables:
- 1 × 3 ml cartridge
- 20 × 31G 5 mm pen tips
- 1 × Reconstitution Kit (4 × alcohol swabs, 1 × 21G needle, 1 × 3 ml syringe)
In practice, the pattern is simple. Starter Kit with the first vial, Refill Kit with each vial after that.
Starter vs Refill at a glance
| Item | Starter Kit | Refill Kit |
|---|---|---|
| 80IU reusable pen body | Yes (1, black) | No |
| 3 ml cartridge | 1 | 1 |
| 31G 5 mm pen tips | 20 | 20 |
| Reconstitution Kit (swabs, 21G needle, 3 ml syringe) | 1 | 1 |
| Peptide vial | Sold separately | Sold separately |
| Bacteriostatic water | Sold separately | Sold separately |
What you still need to add
Two things sit outside both kits, and both matter.
The vial. Pick the compound and strength from the peptide vials collection. Each vial page lists its batch details, and published certificates of analysis live on the COA page. If you haven't read one before, our guide to reading a peptide COA explains the HPLC and mass spec sections.
A diluent. Freeze-dried peptides need to be reconstituted before they can go into a cartridge. Most labs use Genetek bacteriostatic water, which is sterile water with 0.9% benzyl alcohol in a sealed 10 ml ampoule. Benzyl alcohol is a preservative that slows bacterial growth after a container has been opened, which is why it's the common choice for anything that will be accessed more than once. A 2023 review of antimicrobial preservatives in protein and peptide formulations also points out that preservatives have to be matched to the molecule, since some can increase particle formation (Stroppel et al., 2023). Our bacteriostatic water guide covers the alternatives.
From vial to cartridge: the lab workflow
Every lab will have its own SOP, but the general sequence looks like this.
1. Prepare the bench
Let the vial and the water come to room temperature. Lay out the kit on a clean surface and wipe the vial stopper, the ampoule neck area and the cartridge's rubber stopper with the alcohol swabs. Give them a moment to dry.
2. Reconstitute the vial
Using the 3 ml syringe and 21G needle, add the chosen volume of bacteriostatic water to the vial. Run it slowly down the inside wall rather than straight onto the powder, then swirl gently until the cake dissolves. Don't shake it. Vigorous agitation is one of the physical stresses that published stability work links to aggregation in protein and peptide solutions (Manning et al., 2010). For a fuller look at what's actually in that powder cake, see our lyophilised peptides guide.
3. Transfer into the cartridge
Draw the solution back into the syringe. With the pen tip removed, pass the needle through the cartridge's top rubber stopper and transfer the solution into the cartridge. Filling through the stopper with a tip still attached is not how this hardware is designed to be loaded, so keep the tip off for this step.
4. Assemble and label
Seat the filled cartridge in the pen body, fit a fresh 31G tip when the pen is next used, and label the pen or cartridge with the compound, concentration and preparation date. Tips are single-use, which is why each kit carries 20 of them. Used needles and tips go into an approved sharps container.
5. Store it properly
Reconstituted peptide solutions are generally kept refrigerated at 2–8 °C and protected from light. The pen hardware and unopened consumables are fine at room temperature in a clean, dry place. Peptides also stick to some surfaces more than others, and lab studies have shown that the container material and solution composition both affect how much is lost to adsorption (Grohganz et al., 2004). It's another reason to keep transfers to a minimum.
Kit or pre-filled pen?
Not every lab needs to load its own cartridges. Biolabs also sells pre-filled peptide pens, which arrive as a ready-made solution, are made to order and travel by overnight cold-chain courier. A rough way to choose:
- Pick a pre-filled pen if you want the compound ready in solution and you're in an area with reliable overnight delivery.
- Pick a vial plus kit if you want to set your own concentration, prefer a format that's stable at ambient temperature in transit, or you're outside reliable overnight courier routes.
Our pens vs vials guide goes deeper on that trade-off, and the reusable pen hardware guide covers the individual pens, cartridges and tips if you'd rather buy them one by one from reconstitution supplies and hardware.
Why bundle the hardware at all?
Partly it's convenience. One add-on instead of five separate line items. But the bigger reason is consistency. When every vial goes out with the same cartridge, tip and syringe set, labs end up with the same workflow from one batch to the next. Fewer surprises, fewer half-finished preps waiting on a missing syringe, and an easier time writing an SOP that a colleague can follow.
FAQ
Does the Vial-to-Pen kit include a peptide?
No. Both kits are hardware and consumables only. The vial is sold separately, as is bacteriostatic water.
What's the difference between the Starter and Refill kits?
The Starter Kit includes the reusable 80IU pen body. The Refill Kit has the same cartridge, 20 tips and reconstitution kit, but no pen.
Which pen comes in the Starter Kit?
The Biolabs 80IU Re-usable Pen in black. It's built for standard 3 ml cartridges.
Can I reuse pen tips?
No. The 31G 5 mm tips are single-use and should go into a sharps container after use.
How do I add a kit to my order?
Choose the kit on any vial product page and it's added to the cart with that vial. You can also open the Starter Kit or Refill Kit pages directly.
Sources
- Stroppel L, Schultz-Fademrecht T, Cebulla M, et al. Antimicrobial Preservatives for Protein and Peptide Formulations: An Overview. Pharmaceutics. 2023;15(2):563. PMID 36839885.
- Manning MC, Chou DK, Murphy BM, Payne RW, Katayama DS. Stability of protein pharmaceuticals: an update. Pharm Res. 2010;27(4):544–575. PMID 20143256.
- Grohganz H, Rischer M, Brandl M. Adsorption of the decapeptide Cetrorelix depends both on the composition of dissolution medium and the type of solid surface. Eur J Pharm Sci. 2004. PMID 14757490.
Research-use-only notice: Biolabs peptides, vial-to-pen kits, pens, cartridges and reconstitution supplies are sold strictly for laboratory research use and are not for human or veterinary use or consumption. Nothing in this article is medical advice or a dosing instruction, and no specific outcome is promised. This article is for educational purposes only and makes no health or efficacy claims.